MJ Research PTC-225 Peltier Thermal Cycler Base Unit Only, Used
- Make MJ Research
- Hertz Does Not Apply
- Model PTC-225 Peltier Thermal Cycler base unit only
- Serial TD001346
- Weight 30.0 Lb
- Voltage Does Not Apply
- Warranty AS-IS
- Dimensions 30.0in x 20.0in x 20.0in
- Shipping Type FedEx Ground
- Item Condition AS-IS
- Manufacturing Date Does Not Apply
Product Information
MJ Research PTC-225 Tetrad Peltier Gradient Thermal Cycler base unit only. Used - unable to test unit, sold as-is. The MJ Research PTC-225 Gradient Thermal Cycler is recommended for use in labs with high throughput PCR applications. The MJ Research PTC-225 Gradient Thermal Cycler is a robust PCR with the ability to run four individual blocks simultaneously without compromising accuracy and performance. This thermal cycler has a high-density display, on-board point-and-click software navigation, and real-time monitoring for ease of use and accuracy. It has another extraordinary and unique feature: it offers real-time monitoring of cycling temperature, extraordinary temperature uniformity of 0.4C within 30 seconds of arrival at 90C, superb thermal accuracy of blocks within 0.3C of NIST standard at 90C, average across block, and a rapid ramp rate of up to 3.0C/sec.
Key Features- High-density display
- Real-time monitoring of cycling temperature
- Extraordinary temperature uniformity of 0.4C within 30 seconds of arrival at 90C
- Superb thermal accuracy of blocks within 0.3C of NIST standard at 90C
- Rapid ramp rates of up to 3.0C/sec
- Thermal Range: -5 to 105C (but no more than 30C below ambient temperature)
- Thermal Accuracy: 0.3C of programmed target at 90C
- Thermal Uniformity: 0.4C well-to-well within 30 seconds of arrival at 90C
- Ramping Speed: Up to 3C/sec
- Sample Capacity: Four Alpha Block, holds 96 x 0.2 ml tubes or one 96-well microplate/Block
- Line Voltage: 10A @ 200-240 VAC, 50-60Hz
- Ports: One 25-pin 8-bit parallel interface printer port and RS-223 serial port
Metric: 13.6 kg
Imperial: 30 lbs
Metric: 30 cm x 20 cm x 20 cm
Imperial: 11.81 in x 7.87 in x 7.87 in
841989
Harmonized Code DetailsMachinery, plant or laboratory equipment whether or not electrically heated (excluding furnaces, ovens and other equipment of heading 8514), for the treatment of materials by a process involving a change of temperature such as heating, cooking, roasting, distilling, rectifying, sterilising, pasteurising, steam-jet drying, evaporating, vaporising, condensing or cooling, other than machinery or plant of a kind used for domestic purposes; instantaneous or storage water heaters, non-electric. This category is used because the product is an electronically heated laboratory equipment for the treatment of materials by temperature change.
Testimonials
“REUZEit has been a great partner for our used equipment needs and always provide timely updates of new arrivals of consigned equipment.”
“Great company to work with. Tammy completed our first international equipment shipment with ease.”
“Fast response, open to adjusting schedule as needed, and great customer interaction.”