Luminex Labscan 100 Cell Based Assay Analyzer
- Make Luminex
- Hertz 50Hz/60Hz
- Model Labscan 100
- Serial LX100050443302
- Weight 128.0 Lb
- Voltage 120V/220V
- Includes Power cord included |
- Warranty 30-Day Warranty, 100% Parts and Labor
- Dimensions 30.0in x 20.0in x 20.0in
- Shipping Type FedEx Ground
- Item Condition New
- Manufacturing Date Does Not Apply
Product Information
The Luminex Labscan 100 Cell Based Assay Analyzer system enables you to multiplex (simultaneously measure) up to 100 analytes in a single microplate well, using very small samples. The system is fast and cost-effective, delivering bioassay results for nucleic acid assays, receptor-ligand assays, immunoassays, and enzymatic assays. With its remarkable sensitivity and high-tech optics, this analyzer is a game-changer in laboratory analysis. It's classified as a Class 1 used equipment with a 30-Day Warranty, 100% Parts and Labor. This versatile device makes it possible to measure reporter channel dynamic ranges, offers optimal fluidics capabilities, and works with a sample volume of 20 - 200 via a sample loop. The system has an autosensing power supply that supports 100 - 240 VAC, 47 - 63 Hz, and can operate within a temperature range of 15 - 30°C with 20% - 80% relative humidity. The Luminex Labscan 100 Cell Based Assay Analyzer is a powerhouse for any laboratory, delivering precise and efficient results with ease. Embrace the future of bioassay analysis with this exceptional piece of equipment.
Key Features- Enables multiplexing of up to 100 analytes
- Fast and cost-effective bioassay results
- High sensitivity and multiple optics capabilities
- Sample volume of 20 - 200 via sample loop
- Autosensing power supply with 100 - 240 VAC, 47 - 63 Hz
- Operating temperature range of 15 - 30°C with 20% - 80% relative humidity
- Power: autosensing 100 -240 VAC, 47 - 63 Hz
- Operating temperature: 15 - 30°C, 20% - 80% relative humidity non-condensing
- Sensitivity: Detect 1000 fluorochromes phycoerythrin (PE) per xMAP microsphere, Reporter channel dynamic range: 3.5 decades of detection
- Optics: Reporter laser: 532 nm, nominal output 10-15 mW, maximum 500 mW, frequency doubled diode; mode of operation, continuous wave (CW). Classification laser: 635 nm, 9.1 6%, maximum output 25 mW, diode; mode of operation, continuous wave (CW). Reporter detector: Photomultiplier tube, detection bandwidth of 565 585 nm. Classification detector and doublet discriminator: Avalanche photo diodes with temperature compensation
- Fluidics: Sample volume is 20 - 200 via sample loop, Sheath flow rate: 90 L 5 L/second, Sample Injection rate: 1 L/second, Cuvette: 200 microns square flow channel, External sheath/waste containers hold enough volume to run up to two 96-well plates between refills
Metric: 58.06 kg
Imperial: 128.00 lbs
Metric: 23.00 cm x 27.00 cm x 13.00 cm
Imperial: 9.06 in x 10.63 in x 5.12 in
90273020
Harmonized Code DetailsThe chosen harmonized code 90273020 suits this product, as it specifically represents spectrophotometers, spectrometers, and spectrographs using fluorescence, phosphorescence.
Testimonials
“REUZEit has been a great partner for our used equipment needs and always provide timely updates of new arrivals of consigned equipment.”
“Great company to work with. Tammy completed our first international equipment shipment with ease.”
“Fast response, open to adjusting schedule as needed, and great customer interaction.”