Thermo Fisher Orbitrap Elite & LTQ Velos Pro with ETD Mass Spectrometer
- Make Thermo Fisher
- Hertz 50Hz/60Hz
- Model Orbitrap Elite & LTQ Velos Pro with ETD
- Serial ETD10907
- Weight 1367.0 Lb
- Voltage 230V
- Includes Power cord included |
- Warranty AS-IS
- Dimensions 75.0in x 56.0in x 60.0in
- Shipping Type FedEx Ground
- Item Condition AS-IS
- Manufacturing Date Does Not Apply
Product Information
The Thermo Fisher Orbitrap Elite & LTQ Velos Pro with ETD is a high-performance hybrid mass spectrometer renowned for its industry-leading features and capabilities. Validation was attempted by a certified technician, but was unsuccessful. The mass spectrometer is designed for applications such as proteomics, metabolomics, and lipidomics. The high-field Orbitrap analyzer enhances speed, sensitivity, and dynamic range to provide certainty in analytical results, especially when dealing with complex and low abundance samples. The equipment features ultrahigh resolution, ensuring in-depth analysis of isobaric species and molecular weight determination for intact proteins. It also boasts exceptional sensitivity and mass accuracy. Notably, the mass spectrometer has electron transfer dissociation capabilities, along with a wide-ranging dynamic scan power. The make and model of the mass spectrometer is Thermo Fisher Orbitrap Elite & LTQ Velos Pro with ETD, equipped for 230V and 50Hz/60Hz operation.
Key Features- High-field Orbitrap analyzer for enhanced speed, sensitivity, and dynamic range
- Ultrahigh resolution for in-depth analysis of isobaric species and molecular weight determination
- Electron transfer dissociation capability and wide-ranging dynamic scan power
- Designed for proteomics, metabolomics, and lipidomics applications
- Equipped for 230V and 50Hz/60Hz operation
- Mass Range: m/z 50-2000, m/z 200-4000
- Resolution: 60,000 at m/z 400 at a scan rate of 1 Hz, minimum resolution 7,500, maximum resolution >100,000 at m/z 400
- Mass Accuracy: < 3 ppm with external calibration, < 1 ppm using internal calibration
- MS/MS: Electrospray Ionization (ESI)
- Sensitivity: -2 L of a 50 fg/L solution of (Ion Trap) reserpine (100 femtograms total) injected at a flow of 500 L/min will produce a minimum signal-to-noise ratio of 100:1
- Dynamic Range: >5,000 within a single scan guaranteeing specified mass accuracy
- MS Scan Power: MSn, for n = 1 through 10
- ETD: 3 L/min infusion of a 1 pmol/L solution of Angiotensin I will produce an electron transfer dissociation fragmentation efficiency of >15%
- Analog Inputs: One (1) analog input (0-1 V), One (1) analog (0-10 V)
Metric: 621.4 kg
Imperial: 1367 lbs
Metric: 75 cm x 56 cm x 60 cm
Imperial: 29.53 in x 22.05 in x 23.62 in
902720
Harmonized Code Details902720 - The harmonized code 902720 is for 'Spectrometers, such as mass spectrometers'. This code is a suitable classification for the Thermo Fisher Orbitrap Elite & LTQ Velos Pro with ETD mass spectrometer, given its functionality and specifications.
Testimonials
“REUZEit has been a great partner for our used equipment needs and always provide timely updates of new arrivals of consigned equipment.”
“Great company to work with. Tammy completed our first international equipment shipment with ease.”
“Fast response, open to adjusting schedule as needed, and great customer interaction.”