Thermo Scientific Orbitrap Elite & LTQ Velos PRO Mass Spectrometer
- Make Thermo Scientific
- Hertz 50Hz/60Hz
- Model Orbitrap Elite & LTQ Velos PRO
- Serial SN05052B, LTQ40155
- Weight 1367.0 Lb
- Voltage 230V
- Warranty 30-Day Warranty, 100% Parts and Labor
- Dimensions 75.0in x 45.0in x 60.0in
- Shipping Type FedEx Ground
- Item Condition Excellent
- Manufacturing Date Does Not Apply
Product Information
The Thermo Scientific Orbitrap Elite is the industry-leading high-performance hybrid mass spectrometer combining the novel high-field Orbitrap analyzer with the latest dual-pressure linear ion trap, the Thermo Scientific LTQ Velos. The high-field Orbitrap analyzer increases speed, sensitivity, and dynamic range to dig deeper into your samples. The ultrahigh resolution provides certainty in analytical results by enabling molecular weight determination for intact proteins and in-depth analysis of isobaric species. This stunning piece of equipment is especially useful when dealing with complex and low-abundance samples, in applications such as proteomics, metabolomics, and lipidomics. You've never experienced mass spectrometry like this before! Manufacturer Specification Mass Range- m/z 50-2000, m/z 200-4000 Resolution- 60,000 at m/z 400 at a scan rate of 1 Hz, minimum resolution 7,500 maximum resolution >100,000 at m/z 400 Mass Accuracy- < 3 ppm with external calibration, < 1 ppm using internal calibration MS/MS- Electrospray Ionization (ESI) Sensitivity- -2 L of a 50 fg/L solution of (Ion Trap) reserpine (100 femtograms total) injected at a ow of 500 L/min will produce a minimum signal-to-noise ratio of 100:1, for the transition of the isolated protonated molecular ion at m/z 609 to the largest two product ions, m/z 397 and m/z 448, when the mass spectrometer is operated at unit resolution in the full-scan MS/MS mode, scanning the product ion spectrum from m/z 165-615.** Dynamic Range- >5,000 within a single scan guaranteeing specied mass accuracy MS Scan Power- MS n , for n = 1 through 10 ETD- 3 L/min infusion of a 1 pmol/L solution of Angiotensin I will produce an electron transfer dissociation fragmentation efciency of >15% Analog Inputs- One (1) analog input (0-1 V), One (1) analog (0-10 V)
Key Features- High-field Orbitrap analyzer
- Dual-pressure linear ion trap
- Ultrahigh resolution
- MS/MS Electrospray Ionization (ESI)
- Analog Inputs: 0-1 V, 0-10 V
- Mass Range: 50-2000, 200-4000 m/z
- Resolution: 60,000 at m/z 400, minimum resolution 7,500, maximum resolution >100,000 at m/z 400
- Mass Accuracy: <3 ppm with external calibration, <1 ppm using internal calibration
- Sensitivity: -2 L of a 50 fg/L solution of reserpine injected at a ow of 500 L/min will produce a minimum signal-to-noise ratio of 100:1
- Dynamic Range: >5,000 within a single scan guaranteeing specied mass accuracy
- MS Scan Power: MS n, for n = 1 through 10
- ETD: 3 L/min infusion of a 1 pmol/L solution of Angiotensin I will produce an electron transfer dissociation fragmentation efciency of >15%
- Analog Inputs: One (1) analog input (0-1 V), One (1) analog (0-10 V)
Metric: 620 kg
Imperial: 1367 lbs
Metric: 75 cm x 45 cm x 60 cm
Imperial: 29.52 in x 17.73 in x 23.58 in
90272000
Harmonized Code DetailsThe chosen harmonized code for 'Mass spectrometers' is 90272000, which includes gas or smoke analysis apparatus; instruments and apparatus for physical or chemical analysis.