Thermo Fisher Orbitrap Velos Pro & LTQ Velos Pro with ETD Mass Spectrometer
- Make Thermo Fisher
- Hertz 50Hz/60Hz
- Model Orbitrap Velos Pro & LTQ Velos Pro with ETD
- Serial ETD10581
- Weight 1367.0 Lb
- Voltage 230V
- Includes Power cord included |
- Warranty 30-Day Warranty, 100% Parts and Labor
- Dimensions 77.0in x 50.0in x 67.0in
- Shipping Type FedEx Ground
- Item Condition New
- Manufacturing Date Does Not Apply
Product Information
The Thermo Fisher Orbitrap Velos Pro & LTQ Velos Pro with ETD Mass Spectrometer is a state-of-the-art used laboratory equipment. The combination of proven mass accuracy and ultra-high resolution provided by the Orbitrap mass analyzer with the sensitivity and cycle time of the LTQ Velos makes this equipment highly reliable and precise. It displays high mass accuracy to increase the speed and confidence of identification in complex samples, making it invaluable for proteomics and metabolomics research. The integrated Electron Transfer Dissociation (ETD) function generates complementary information for highly sensitive PTM analyses and de novo sequencing, providing a wide range of options for conducting cutting-edge research and extending the boundaries of mass spectrometry. This equipment opens up possibilities for identifying intact proteins and in-depth analysis of isobaric species, and with its increased sensitivity, it can minimize false positive identification for more accurate results. It's like having a high-powered telescope for viewing molecular structures and interactions.
Key Features- High mass accuracy and ultra-high resolution for precise results
- Electron Transfer Dissociation (ETD) for sensitive PTM analyses
- Increased sensitivity to minimize false positive identification
- Manufacture Specification
- Mass Range- m/z 50-2000, m/z 200-4000
- Resolution- 60,000 at m/z 400 at a scan rate of 1 Hz, minimum resolution 7,500 maximum resolution >100,000 at m/z 400
- Mass Accuracy- < 3 ppm with external calibration, < 1 ppm using internal calibration
- MS/MS- Electrospray Ionization (ESI)
- Sensitivity- -2 L of a 50 fg/L solution of (Ion Trap) reserpine (100 femtograms total) injected at a ow of 500 L/min will produce a minimum signal-to-noise ratio of 100:1, for the transition of the isolated protonated molecular ion at m/z 609 to the largest two product ions, m/z 397 and m/z 448, when the mass spectrometer is operated at unit resolution in the full-scan MS/MS mode, scanning the product ion spectrum from m/z 165-615.**
- Dynamic Range- >5,000 within a single scan guaranteeing specied mass accuracy
- MS Scan Power- MS n , for n = 1 through 10
- ETD option- 3 L/min infusion of a 1 pmol/L solution of Angiotensin I will produce an electron transfer dissociation fragmentation efciency of >15%
- Analog Inputs- One (1) analog input (0-1 V), One (1) analog (0-10 V)
Metric: 621 kg
Imperial: 1367 lbs
Metric: 69 cm x 34 cm x 56 cm
Imperial: 27.2 in x 13.4 in x 22 in
90272000
Harmonized Code Details90272000 - Chromatographs and electrophoresis instruments