Agilent 1100 Series HPLC System with Vacuum Degasser and Variable Wavelength Detector
- Make Agilent
- Hertz 50Hz/60Hz
- Model 1100 Series
- Serial JP03925566
- Weight 188.0 Lb
- Voltage 120V/220V
- Includes All cables (power and data) included |
- Warranty 30-Day Warranty, 100% Parts and Labor
- Dimensions 28.0in x 26.0in x 48.0in
- Shipping Type FedEx Ground
- Item Condition Excellent
- Manufacturing Date Does Not Apply
Product Information
The Agilent 1100 Series HPLC System is both remarkably easy-to-use and maintenance-free, featuring a high-speed proportioning valve and a pre-configured degasser, allowing for convenient low-pressure mixing and a large solvent choice flexibility. The vacuum degasser ensures reduced operating costs without the use of helium and optimum instrument performance. The Variable Wavelength Detector lowers detection limits with simplified optics for high sensitivity, low baseline drift, and wide linear range. Suitable applications include pharmaceutical research, environmental testing, and food safety analysis.
Key Features- Easy-to-use and maintenance-free design
- Pre-configured vacuum degasser for reduced operating costs and optimum instrument performance
- Variable Wavelength Detector with high sensitivity and low baseline drift
- Programmable wavelength switching for sensitivity and optimized selectivity
- Detection type: Double-beam photometer
- Wavelength Range: 190 - 600 nm
- Short Term Noise (ASTM) Single and Multi-Wavelength: 0.75 10^-5 AU at 254 nm
- Drift: 3 10^-4 AU/hr at 254 nm
- Linear Absorbance Range: > 2 AU (5%) upper limit
- Wavelength Accuracy: 1 nm
- Slit Width: 1, 2, 4, 8, 16 nm
- Band Width: 6.5 nm typical
- Diode Width: < 1 nm
- Flow Cells: Standard - 14-l volume, 10-mm cell path length and 40 bar (588 psi) pressure maximum
- Control and Data Evaluation: Agilent ChemStation for LC
- Analog Outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 - 2 AU, two outputs
Metric: 60 kg
Imperial: 132 lbs
Metric: 48.0 cm x 47.0 cm x 122.0 cm
Imperial: 18.9 in x 18.5 in x 48.0 in
9027300000
Harmonized Code DetailsThe harmonized code 9027300000 is for liquid chromatograph apparatus. This code is chosen due to the inclusion of the HPLC System's key components and its function in separating, identifying, and quantifying compounds in the liquid phase.
Testimonials
“REUZEit has been a great partner for our used equipment needs and always provide timely updates of new arrivals of consigned equipment.”
“Great company to work with. Tammy completed our first international equipment shipment with ease.”
“Fast response, open to adjusting schedule as needed, and great customer interaction.”