Thermo Fisher LTQ Orbitrap Velos & LTQ Velos with ETD Mass Spec
- Make Thermo Fisher
- Hertz 50Hz/60Hz
- Model LTQ Orbitrap Velos & LTQ Velos with ETD
- Serial ETD10575/30507
- Weight 1367.0 Lb
- Voltage 230V
- Warranty AS-IS
- Dimensions 74.0in x 50.0in x 66.0in
- Shipping Type FedEx Ground
- Item Condition Good
- Manufacturing Date Does Not Apply
Product Information
"The Thermo Scientic LTQ Orbitrap Velos combines the proven mass accuracy and ultra-high resolution of the Orbitrap mass analyzer, with the increased sensitivity and improved cycle time of the LTQ Velos. The high mass accuracy of the LTQ Orbitrap Velos increases the speed and condence of identication in complex samples by minimizing false positive identication. The ultra-high resolution provides certainty in analytical results by enabling molecular weight determination for intact proteins and in-depth analysis of isobaric species. The new HCD cell in the LTQ Orbitrap Velos is more efcient, resulting in improved quantitation of isobaricallylabeled peptides, such as applications requiring Tandem Mass Tags (TMT). Electron Transfer Dissociation (ETD) generates complementary information for highly sensitive PTM analyses and de novo sequencing. Installation (IQ/OQ), training and service contracts available for additional cost. Manufacture Specification Mass Range- m/z 50-2000, m/z 200-4000 Resolution- 60,000 at m/z 400 at a scan rate of 1 Hz, minimum resolution 7,500 maximum resolution >100,000 at m/z 400 Mass Accuracy- < 3 ppm with external calibration, < 1 ppm using internal calibration MS/MS- Electrospray Ionization (ESI) Sensitivity- -2 L of a 50 fg/L solution of (Ion Trap) reserpine (100 femtograms total) injected at a ow of 500 L/min will produce a minimum signal-to-noise ratio of 100:1, for the transition of the isolated protonated molecular ion at m/z 609 to the largest two product ions, m/z 397 and m/z 448, when the mass spectrometer is operated at unit resolution in the full-scan MS/MS mode, scanning the product ion spectrum from m/z 165-615.** Dynamic Range- >5,000 within a single scan guaranteeing specied mass accuracy MS Scan Power- MS n , for n = 1 through 10 ETD option- 3 L/min infusion of a 1 pmol/L solution of Angiotensin I will produce an electron transfer dissociation fragmentation efciency of >15% Analog Inputs- One (1) analog input (0-1 V), One (1) analog (0-10 V) Thermo Flex900 Temperature Range (Metric) 5 to 40C Cooling Capacity Up to 900 watts (60Hz) 750 watts (50Hz) Voltage Multiple options Temperature Stability 0.1C Description ThermoFlex 900 Recirculating Chiller Certifications/Compliance CE, CSA Condenser Type Air Cooled Pump Capacity Up to 3.3 gpm @ 60 psig (12.5 lpm @ 4.1 bar) (50Hz) Up to 4.0 gpm @ 60 psig (15.1 lpm @ 4.1 bar) (60Hz) Communications Analog & Digital available Powervar Series 2000 GPI Series: GPI 2000 Model: ABC15.0-20D40Y P/N: 74015-54R Input: 208V Output: 400/233V Load: 15kVA Phase: 3 Connection DELTA Connection: WYE Enclosure Type: NEMA 1 Edwards 30 Rotary Vane Pump (X2) Maximum Displacement 19 cfm at 50 Hz 23 cfm at 60 Hz Maximum Speed 16.2 cfm at 50 Hz 19.4 cfm at 60 Hz Motor Rotational Speed 1440 r min-1 1720 r min-1 Ultimate Vacuum Without gas-ballast: 1 x 10-3 mbar With gas-ballast: 1.5 x 10-2 mbar With Fomblin: 1 x 10-2 mbar Noise Level 57 dB(A) at 50 Hz Maximum Water Vapor Inlet Pressure 30 mbar / 23 torr Maximum Water Vapor Pumping Rate 0.7 kg h-1 Maximum Permitted Outlet Pressure (at full pump throughput) 0.5 bar gauge 1.5 bar absolute 1.5 x 105 Pa Electrical Supply 200-240 V, 50 Hz 230-240 V, 60 Hz "
Key Features- Ultra-high mass accuracy
- Increased sensitivity
- Resolution of isobaric species
- Electron Transfer Dissociation (ETD) for PTM analyses and de novo sequencing
- Maximize quantitation for isobarically labeled peptides
- Mass Range: m/z 50-2000, m/z 200-4000
- Resolution: 60,000 at m/z 400 at a scan rate of 1 Hz, minimum resolution 7,500 maximum resolution >100,000 at m/z 400
- Mass Accuracy: < 3 ppm with external calibration, < 1 ppm using internal calibration
- Sensitivity: -2 L of a 50 fg/L solution of (Ion Trap) reserpine (100 femtograms total) injected at a ow of 500 L/min will produce a minimum signal-to-noise ratio of 100:1
- Dynamic Range: >5,000 within a single scan guaranteeing specied mass accuracy
- ETD Option: 3 L/min infusion of a 1 pmol/L solution of Angiotensin I will produce an electron transfer dissociation fragmentation efciency of >15%
- Analog Inputs: One (1) analog input (0-1 V), One (1) analog (0-10 V)
- Dimension(cm): 69L x 34W x 56H
- Weight(metric): 1367 kg
- Voltage: 230-240 V, 50 Hz, 230-240 V, 60 Hz
Metric: 1367 kg
Imperial: 3013.45 lbs
Metric: 69 cm x 34 cm x 56 cm
Imperial: 27.17 in x 13.39 in x 22.05 in
902720
Harmonized Code DetailsMass spectrometers category is harmonized under code 902720 for the apparatus based on the use of X-ray or of alpha, beta or gamma radiations, whether or not for medical, surgical, dental or veterinary uses, including radiography or radiotherapy apparatus and screens.
Testimonials
“REUZEit has been a great partner for our used equipment needs and always provide timely updates of new arrivals of consigned equipment.”
“Great company to work with. Tammy completed our first international equipment shipment with ease.”
“Fast response, open to adjusting schedule as needed, and great customer interaction.”