Used Waters HPLC System with Detector and Column Heater - H96SM7142M
- Make Waters
- Hertz 50Hz/60Hz
- Model HPLC Sep. Module w/ Detector and Column Heater
- Serial H96SM7142M
- Weight 260.0 Lb
- Voltage 120V
- Includes Power cord included |
- Warranty AS-IS
- Dimensions 30.0in x 25.0in x 39.0in
- Shipping Type FedEx Ground
- Item Condition Good
- Manufacturing Date Does Not Apply
Product Information
Ah, the Waters 2695 HPLC System! A marvel born out of the delightful fusion of solvent and sample management. High injection precision for fine quantification! Retention time repeatability ensuring accurate peak identification. Churning out predictable results thanks to quaternary blending and pulse-free solvent delivery. But, what truly sets the 2695 apart? It's got advanced capabilities in spades!
Key Features- Innovative quaternary blending for consistent results
- Pulse-free solvent delivery through serial flow path
- Advanced capabilities for precise quantification
- Number of solvents: One to four
- Solvent conditioning: Vacuum degas, two operating modes, four chambers, <500 uL internal volume per chamber>
- Programmable flow rate range: 0.000 to 10.000 mL/min in 0.001-mL/min. increments
- Typical operating flow rate range: 0.050 to 5.000 mL/min in 0.001-mL/min increments
- Compressibility compensation: Automatic and continuous
- Effective system delay volume: <650 L, independent of backpressure @ 1 mL/min
- Plunger seal wash: Integra, active, programmable
- Gradient profiles: Eleven gradient curves including linear, step (2 curves), concave (4 curves), and convex (4 curves)
- Flow ramping: Time (0.01 to 30.00 min in 0.01-min increments) to reach maximum flow rate
- Maximum operating pressure: 5000 psi (345 bar) (0.010 to 3.000 mL/min)
- Pressure ripple: 2.5% (1 mL/min, degassed methanol, at 1700 psi backpressure)
- Composition accuracy: 0.5% absolute, independent of backpressure
- Composition precision: 0.15% RSD or 0.02 min SD, based on retention time, six replicates, phenone mix, 254 nm
- Flow precision: 0.075% RSD or 0.02 min SD, based on retention time, volumetric measures (0.200 to 5.000 mL/min)
- Flow accuracy: 1% or 10 L/min, degassed methanol, at 600 psi backpressure
Metric: 117.9348 kg
Imperial: 260 lbs
Metric: 76.2 cm x 63.5 cm x 99.06 cm
Imperial: 30 in x 25 in x 39 in
9027200000
Harmonized Code DetailsThe harmonized code 9027200000 is for liquid chromatography instruments. The Waters HPLC system clearly falls within this category due to its use of high-performance liquid chromatography technology.
Testimonials
“REUZEit has been a great partner for our used equipment needs and always provide timely updates of new arrivals of consigned equipment.”
“Great company to work with. Tammy completed our first international equipment shipment with ease.”
“Fast response, open to adjusting schedule as needed, and great customer interaction.”