Thermo Fisher TSQ Endura Triple Quadruple Mass Spectrometer
- Make Thermo Fisher
- Hertz 50Hz/60Hz
- Model TSQ Endura
- Serial TQH-E1-0104
- Weight 310.0 Lb
- Voltage 220V
- Includes Computer with software included | Power cord included |
- Warranty 30-Day Warranty, 100% Parts and Labor
- Dimensions 48.0in x 40.0in x 35.0in
- Shipping Type FedEx Ground
- Item Condition New
- Manufacturing Date Does Not Apply
Product Information
From forensic toxicology to environmental analysis to pharmaceutical research, a constant in almost every field is the need for greater productivity. The Thermo Scientific Endura Triple Quadruple Mass Spectrometer meets these needs with unsurpassed value. It delivers best-in-class sensitivity run after run and day after day regardless of sample type or matrix, and does so with an ease-of-use that takes the worry out of method development and operation. This Thermo Fisher TSQ Endura has a warranty of 30 days with 100% parts and labor. "The is the workhorse of the lab, consistently reliable and accurate."
Key Features- Best-in-class sensitivity and reliability
- Ease-of-use for method development and operation
- Warranty of 30 days with 100% parts and labor
- Includes Computer with Software, Peak Scientific Genius Nitrogen Gas Generator, Powervar ABCDEF6000-22 Security Plus, Sogevac SV40/65 Rotary Pump
- Positive Electrospray (HESI): A 2 L injection of a 500 fg/L reserpine solution will produce a minimum signal-to-noise ratio of 80,000:1 for the transition of the protonated molecule at m/z 609.3 to the fragment ion at m/z 195.1 when operated in selected-reaction monitoring (SRM) mode with Q1 and Q3 resolution set to 0.4 and 0.7 Da FWHM respectively.
- Atmospheric Pressure Chemical Ionization (APCI): A 2 L loop injection of a 500 fg/L reserpine solution will produce a minimum signal-to-noise ratio of 25,000:1 for the transition of the protonated molecular ion at m/z 609.3 to the fragment ion at m/z 195.1 when operated in selected reaction monitoring (SRM) mode with Q1 and Q3 resolution both set to 0.7 Da FWHM.
- Negative Electrospray (nESI): A 2 L loop injection of a 500 fg/uL chloramphenicol solution will produce a minimum signal-to-noise ratio of 80,000:1 for the transition of the deprotonated molecular ion at m/z 321.0 to the fragment ion at m/z 152.0 when operated in selected reaction monitoring mode (SRM) with Q1 and Q3 resolution set to 0.4 and 0.7 Da FWHM, respectively.
- Mass Range: m/z 103400
- Resolution: Q1 and Q3 adjustable to 0.4 Da peak width (FWHM) across the entire mass range
- Scan Rate: 15,000 amu/second at a resolution of 2 FWHM
- 500 SRM/second (for any resolution from 0.4 through 2.0 FWHM)
- 25msec polarity switching
- Mass Stability: Mass assignment will be within 0.05 Da over a 24 hour period. The laboratory room temperature must be maintained between 18-27 C (65-81 F). The room temperature may not change by more than 5 C (9 F) during this period.
Metric: 140.61 kg
Imperial: 310 lbs
Metric: 121.92 cm x 101.6 cm x 88.9 cm
Imperial: 48 in x 40 in x 35 in
9027200000
Harmonized Code DetailsMass spectrometers; for measuring or checking the flow or level of liquids, nesoi