Geneforce Indoor Battery Generator GEN-2030H (120V-240V) - Used
Geneforce Indoor Battery Generator GEN-2030H (120V-240V) - Used
Geneforce Indoor Battery Generator GEN-2030H (120V-240V) - Used
Geneforce Indoor Battery Generator GEN-2030H (120V-240V) - Used
Geneforce Indoor Battery Generator GEN-2030H (120V-240V) - Used
Geneforce Indoor Battery Generator GEN-2030H (120V-240V) - Used
Geneforce Indoor Battery Generator GEN-2030H (120V-240V) - Used
Geneforce Indoor Battery Generator GEN-2030H (120V-240V) - Used
Geneforce Indoor Battery Generator GEN-2030H (120V-240V) - Used
Geneforce Indoor Battery Generator GEN-2030H (120V-240V) - Used
Geneforce Indoor Battery Generator GEN-2030H (120V-240V) - Used
Geneforce Indoor Battery Generator GEN-2030H (120V-240V) - Used

Geneforce Indoor Battery Generator GEN-2030H (120V-240V) - Used

sku: 3362579
1 In Stock
Ask a question
Condition : Good
Warranty : 30-Day Warranty, 100% Parts and Labor
Region : US
$10,500.00
Apply For Finance
Make Offer
Enquiry Here
ADD TO CART
  • Make Geneforce
  • Hertz 50Hz/60Hz
  • Model GEN-2030H
  • Serial N/A
  • Weight 1915.0 Lb
  • Voltage 120V/220V
  • Includes Power cord included |
  • Warranty 30-Day Warranty, 100% Parts and Labor
  • Dimensions 34.0in x 46.0in x 49.0in
  • Shipping Type Freight
  • Item Condition Good
  • Manufacturing Date Does Not Apply

Product Information

The Geneforce Indoor Battery Generator is a gas-free power source that does not emit any harmful fumes or gases. The Geneforce Indoor Generator is silent, mobile and starts automatically or with one-touch of a button.The Geneforce does not rely on gas and, thus, is safe for indoors. The Geneforce Battery Generators can provide backup power for several hours, days or weeks on a single charge. The Geneforce Indoor Generator features a standby mode that is ready for any power failure. **Unit has slight cosmetic damage on the right and left side. See attached pictures for more details. Manufacture Specification Electrical Specifications GEN-2030H (120V-240V) Output power (continuous) at 25C: 3,000 W Output power (30 min) at 25C: 3,300 W Output power (5 sec) at 25C: 5,000 W Peak current: 24.3 A Output frequency: 50 / 60 Hz selectable Output voltage: 120 / 240 Vac Output wave form: True sine wave Input DC voltage range: 20-34 Vdc AC connections: Single / Split phase Charger Output current: 65 A Output voltage range: 12-32 Vdc Charge control: 2 or 3 stages Charge temperature compensation: Battery temperature sensor included Input current: 9 A Input AC voltage: 120 / 240 Vac split phase Input AC voltage range line to neutral: 95 - 135 Vac single phase; 170 - 270 Vac AC input voltage requirements: 240V default *phase between L (1) and L (2) must be 180 to qualify AC AC input 1: One 30A, 250 Volt, NEMA L14-30P, 3P, 4W, locking plug with 8 ft. cord AC output 1: Four (20A/125V) NEMA 5-20R isolated ground receptacles AC output 2: One 30A, 125/250 Volt, NEMA L14-30R, 3P, 4W, locking receptacle Dead battery charge: Yes Battery bank reserve power: 24 kW (24,000 Watts) Battery service life: 12-16 years on float Solar charge controller: 30A/12V (~360 W per hour/sunlight) *(60A/12V-24V) optional General Specifications Transfer relay rating: 30A Transfer time (AC to inverter and inverter to AC) <1 cycle (16.7ms) Optimal operating temperature range: -20C to 60C (-4F to 140F) Ingress protection rating: Indoor only, IP20 Regulatory approval Safety: Components are (CSA) us mark CSA C22.2, No. 107.1-01 UL1741 Ed.2 EMC directive: FCC Part 15 Class B Part Number: GEN-2030H-120240-3000-16

Key Features

  • Gas-free power source
  • Backup power for several hours, days, or weeks
  • Silent and mobile
  • Automatic start or one-touch button start
  • Standby mode for power failure
Specifications

  • Output power (continuous) at 25C: 3,000 W
  • Output power (30 min) at 25C: 3,300 W
  • Output power (5 sec) at 25C: 5,000 W
  • Peak current: 24.3 A
  • Output frequency: 50 / 60 Hz selectable
  • Output voltage: 120 / 240 Vac
  • Output wave form: True sine wave
  • Input DC voltage range: 20-34 Vdc
  • AC connections: Single / Split phase
  • Charger output current: 65 A
  • Charger output voltage range: 12-32 Vdc
  • Charge control: 2 or 3 stages
  • Charge temperature compensation: Battery temperature sensor included
  • Input current: 9 A
  • Input AC voltage: 120 / 240 Vac split phase
  • Input AC voltage range line to neutral: 95 - 135 Vac single phase; 170 - 270 Vac
  • AC input voltage requirements: 240V default
  • Dead battery charge: Yes
  • Battery bank reserve power: 24 kW (24,000 Watts)
  • Battery service life: 12-16 years on float
  • Solar charge controller: 30A/12V (~360 W per hour/sunlight) *(60A/12V-24V) optional
  • Transfer relay rating: 30A Transfer time (AC to inverter and inverter to AC) <1 cycle (16.7ms)
  • Optimal operating temperature range: -20C to 60C (-4F to 140F)
  • Ingress protection rating: Indoor only, IP20
  • Regulatory approval: Components are (CSA) us mark CSA C22.2, No. 107.1-01 UL1741 Ed.2 EMC directive FCC Part 15 Class B
  • Part Number: GEN-2030H-120240-3000-16
Weight

Metric: 870 kg
Imperial: 1915 lb

Dimensions

Metric: 34.00 cm x 46.00 cm x 49.00 cm
Imperial: 13.39 in x 18.11 in x 19.29 in

Harmonized Code

850220

Harmonized Code Details

Electric generating sets and rotary converters

Testimonials

★★★★★

“REUZEit has been a great partner for our used equipment needs and always provide timely updates of new arrivals of consigned equipment.”

★★★★★

“Great company to work with. Tammy completed our first international equipment shipment with ease.”

★★★★★

“Fast response, open to adjusting schedule as needed, and great customer interaction.”

Need Answers? We’re Here to Help