Thermo Fisher LTQ Orbitrap Velos & LTQ Velos Mass Spectrometer with ThermoFlex 900 Chiller and Edwards 30 Rotary Vane Pump (X2)
- Make Thermo Fisher
- Hertz 50Hz/60Hz
- Model LTQ Orbitrap Velos & LTQ Velos
- Serial ETD10459, 30239
- Weight 1367.0 Lb
- Voltage 230V
- Includes Power cord included |
- Warranty 30-Day Warranty, 100% Parts and Labor
- Dimensions 69.0in x 34.0in x 56.0in
- Shipping Type FedEx Ground
- Item Condition Excellent
- Manufacturing Date Does Not Apply
Product Information
"The Thermo Scientic LTQ Orbitrap Velos combines the proven mass accuracy and ultra-high resolution of the Orbitrap mass analyzer, with the increased sensitivity and improved cycle time of the LTQ Velos. The high mass accuracy of the LTQ Orbitrap Velos increases the speed and condence of identication in complex samples by minimizing false positive identication. The ultra-high resolution provides certainty in analytical results by enabling molecular weight determination for intact proteins and in-depth analysis of isobaric species. The new HCD cell in the LTQ Orbitrap Velos is more efcient, resulting in improved quantitation of isobaricallylabeled peptides, such as applications requiring Tandem Mass Tags (TMT). Electron Transfer Dissociation (ETD) generates complementary information for highly sensitive PTM analyses and de novo sequencing. Manufacture Specification. Mass Range- m/z 50-2000, m/z 200-4000. Resolution- 60,000 at m/z 400 at a scan rate of 1 Hz, minimum resolution 7,500 maximum resolution >100,000 at m/z 400. Mass Accuracy- < 3 ppm with external calibration, < 1 ppm using internal calibration. MS/MS- Electrospray Ionization (ESI). Sensitivity- -2 L of a 50 fg/L solution of (Ion Trap) reserpine (100 femtograms total) injected at a ow of 500 L/min will produce a minimum signal-to-noise ratio of 100:1, for the transition of the isolated protonated molecular ion at m/z 609 to the largest two product ions, m/z 397 and m/z 448, when the mass spectrometer is operated at unit resolution in the full-scan MS/MS mode, scanning the product ion spectrum from m/z 165-615.** Dynamic Range- >5,000 within a single scan guaranteeing specied mass accuracy. MS Scan Power- MS n , for n = 1 through 10. ETD- 3 L/min infusion of a 1 pmol/L solution of Angiotensin I will produce an electron transfer dissociation fragmentation efciency of >15%. Analog Inputs- One (1) analog input (0-1 V), One (1) analog (0-10 V). Thermo Flex900... Cooling CapacityUp to 900 watts (60Hz) 750 watts (50Hz)... 230-240 V, 50 Hz"
Key Features- Thermo Scientic LTQ Orbitrap Velos combined mass accuracy & ultra-high resolution of Orbitrap mass analyzer with LTQ Velos
- High mass accuracy reduces false positives & increases speed of identification
- Ultra-high resolution supports molecular weight determination, in-depth isobaric species analysis
- HCD cell efficiency for improved quantitation of peptides
- Electron Transfer Dissociation for highly sensitive PTM analyses & de novo sequencing
- ThermoFlex 900 Recirculating Chiller for temperature control, stability
- Edwards 30 Rotary Vane Pump (X2) for high displacement capacity, operational efficiency
- Mass Range: m/z 50-2000, m/z 200-4000
- Resolution: 60,000 at m/z 400 at a scan rate of 1 Hz, minimum resolution 7,500, maximum resolution >100,000 at m/z 400
- Mass Accuracy: < 3 ppm with external calibration, < 1 ppm using internal calibration
- MS/MS: Electrospray Ionization (ESI)
- Dynamic Range: >5,000 within a single scan guaranteeing specified mass accuracy
- MS Scan Power: MS n, for n = 1 through 10
- ETD: 3 L/min infusion of a 1 pmol/L solution of Angiotensin I will produce an electron transfer dissociation fragmentation efficiency of >15%
- Analog Inputs: One (1) analog input (0-1 V), One (1) analog (0-10 V)
- ThermoFlex 900 Recirculating Chiller
- Cooling Capacity: Up to 900 watts (60Hz) 750 watts (50Hz)
- Voltage: 230-240 V, 50 Hz
- Edwards 30 Rotary Vane Pump (X2)
- Maximum Displacement: 19 cfm at 50 Hz and 23 cfm at 60 Hz
- Motor Rotational Speed: 1440 r min-1 at 50 Hz, 1720 r min-1 at 60 Hz
- Ultimate Vacuum: Without gas-ballast: 1 x 10-3 mbar, With gas-ballast: 1.5 x 10-2 mbar
Metric: 621.0 kg
Imperial: 1367.0 lbs
Metric: 69 cm x 34 cm x 56 cm
Imperial: 27.2 in x 13.4 in x 22.0 in
9027200000
Harmonized Code DetailsThe chosen harmonized code specifically covers mass spectrometers used in laboratory, pharmaceutical, or other scientific settings. Its high accuracy, resolution, and compatibility with advanced techniques make it suitable for a research and development environment.
Testimonials
“REUZEit has been a great partner for our used equipment needs and always provide timely updates of new arrivals of consigned equipment.”
“Great company to work with. Tammy completed our first international equipment shipment with ease.”
“Fast response, open to adjusting schedule as needed, and great customer interaction.”