Thermo Scientific LTQ Orbitrap Velos & Velos Pro with ETD Mass Spec
- Make Thermo Scientific
- Hertz 60Hz US
- Model LTQ Orbitrap Velos & Velos Pro with ETD
- Serial ETD10421, 30208, SN03070B
- Weight 1367.0 Lb
- Voltage 220V
- Warranty 30-Day Warranty, 100% Parts and Labor
- Dimensions 79.0in x 44.0in x 66.0in
- Shipping Type FedEx Ground
- Item Condition Excellent
- Manufacturing Date Does Not Apply
Product Information
The Thermo Scientic LTQ Orbitrap Velos combines the proven mass accuracy and ultra-high resolution of the Orbitrap mass analyzer, with the increased sensitivity and improved cycle time of the LTQ Velos. The high mass accuracy of the LTQ Orbitrap Velos increases the speed and condence of identication in complex samples by minimizing false positive identication. The ultra-high resolution provides certainty in analytical results by enabling molecular weight determination for intact proteins and in-depth analysis of isobaric species. The new HCD cell in the LTQ Orbitrap Velos is more efcient, resulting in improved quantitation of isobaricallylabeled peptides, such as applications requiring Tandem Mass Tags (TMT). Electron Transfer Dissociation (ETD) generates complementary information for highly sensitive PTM analyses and de novo sequencing. Manufacture Specification Mass Range- m/z 50-2000, m/z 200-4000 Resolution- 60,000 at m/z 400 at a scan rate of 1 Hz, minimum resolution 7,500 maximum resolution >100,000 at m/z 400 Mass Accuracy- < 3 ppm with external calibration, < 1 ppm using internal calibration MS/MS- Electrospray Ionization (ESI) Sensitivity- -2 L of a 50 fg/L solution of (Ion Trap) reserpine (100 femtograms total) injected at a ow of 500 L/min will produce a minimum signal-to-noise ratio of 100:1, for the transition of the isolated protonated molecular ion at m/z 609 to the largest two product ions, m/z 397 and m/z 448, when the mass spectrometer is operated at unit resolution in the full-scan MS/MS mode, scanning the product ion spectrum from m/z 165-615.** Dynamic Range- >5,000 within a single scan guaranteeing specied mass accuracy MS Scan Power- MS n , for n = 1 through 10 ETD option- 3 L/min infusion of a 1 pmol/L solution of Angiotensin I will produce an electron transfer dissociation fragmentation efciency of >15% Analog Inputs- One (1) analog input (0-1 V), One (1) analog (0-10 V)
Key Features- Ultra-high resolution Orbitrap mass analyzer
- Increased sensitivity and improved cycle time of the LTQ Velos
- Electron Transfer Dissociation (ETD) option
- Analog Inputs: One (1) analog input (0-1 V), One (1) analog (0-10 V)
- Mass Range: m/z 50-2000, m/z 200-4000
- Resolution: 60,000 at m/z 400 at a scan rate of 1 Hz, minimum resolution 7,500 maximum resolution >100,000 at m/z 400
- Mass Accuracy: < 3 ppm with external calibration, < 1 ppm using internal calibration
- MS/MS: Electrospray Ionization (ESI)
- Sensitivity: -2 L of a 50 fg/L solution of (Ion Trap) reserpine (100 femtograms total) injected at a ow of 500 L/min will produce a minimum signal-to-noise ratio of 100:1
- Dynamic Range: >5,000 within a single scan guaranteeing specified mass accuracy
- ETD option: 3 L/min infusion of a 1 pmol/L solution of Angiotensin I will produce an electron transfer dissociation fragmentation efficiency of >15%
- Analog Inputs: One (1) analog input (0-1 V), One (1) analog (0-10 V)
Metric: 621.39 kg
Imperial: 1367 lbs
Metric: 69 cm x 34 cm x 56 cm
Imperial: 27.17 in x 13.39 in x 22.05 in
9027200000
Harmonized Code DetailsMass spectrometers; mass spectrometric instruments; other instruments, appliances and machines