Mettler Toledo Volumetric KF Compact Titrator V30
Mettler Toledo Volumetric KF Compact Titrator V30
Mettler Toledo Volumetric KF Compact Titrator V30
Mettler Toledo Volumetric KF Compact Titrator V30
Mettler Toledo Volumetric KF Compact Titrator V30
Mettler Toledo Volumetric KF Compact Titrator V30
Mettler Toledo Volumetric KF Compact Titrator V30
Mettler Toledo Volumetric KF Compact Titrator V30
Mettler Toledo Volumetric KF Compact Titrator V30
Mettler Toledo Volumetric KF Compact Titrator V30
Mettler Toledo Volumetric KF Compact Titrator V30
Mettler Toledo Volumetric KF Compact Titrator V30
Mettler Toledo Volumetric KF Compact Titrator V30
Mettler Toledo Volumetric KF Compact Titrator V30
Mettler Toledo Volumetric KF Compact Titrator V30
Mettler Toledo Volumetric KF Compact Titrator V30
Mettler Toledo Volumetric KF Compact Titrator V30
Mettler Toledo Volumetric KF Compact Titrator V30
Mettler Toledo Volumetric KF Compact Titrator V30
Mettler Toledo Volumetric KF Compact Titrator V30

Mettler Toledo Volumetric KF Compact Titrator V30

sku: 3376845
Out Of Stock
Ask a question
Condition : Pre-owned
Warranty : 30-Day Warranty, 100% Parts and Labor
Region : US
$750.00
Apply For Finance
Make Offer
Enquiry Here
ADD TO CART
  • Make Mettler Toledo
  • Hertz 50Hz/60Hz
  • Model V30
  • Serial B550828223
  • Weight 17
  • Voltage 120V
  • Working Working
  • Includes Power Cord
  • Warranty 30-Day Warranty, 100% Parts and Labor
  • Dimensions 21×16×24 in
  • Shipping Type FedEx Ground
  • Item Condition Pre-owned

Mettler Toledo Compact Volumetric KF Titrator V30

**This unit has been tested to specifications. Has scratch front device. Buyer can expect working unit with 30-Day warranty. See photos for further details

One Click Water Determination - Flexible, Simple & Secure. The all-round Karl Fischer titrator is the flexible and powerful instrument for fast and precise water determination of samples from any industry with a water content between 100 ppm and 100%. Karl Fischer titration is used for many substances as a reference method, and is a chemical analysis based on the oxidation of sulfur dioxide by iodine in a methanolic hydroxide solution. In principle, the following chemical reaction takes place:

H2O + I2 + SO2 + CH3OH + 3RN -> [RNH]SO4CH3 + 2[RNH]I

The titration can be performed volumetrically or coulometrically. In the volumetric method a Karl Fischer solution containing iodine is added until the first trace of excess iodine is present. The amount of iodine converted is determined from the burette volume of the iodine-containing Karl Fischer solution. Titration Compact devices can either be controlled by touchscreen or by using LabX PC software. 

One Click User Interface for Simple and Secure Operation
The large color Touchscreen features the simple-to-understand and fast-to-operate One Click user interface. All users have their own Home screen with dedicated Shortcut buttons to directly start specific routine tasks. Users are familiar from the start and make fewer errors in operation.

Generalists 
for Water Determination up to 100%
The Compact Volumetric Karl Fischer Titrators have been designed for a wide range of water content applications: determinations from 100 ppm to 100% water — fast and precisely. The titration vessel is optimized to retain a low drift value and offers the possibility to determine the water content of liquid, solid and gaseous samples.

The Fast and Most Precise Solution — for Very Low Water Content
Accuracy and precision is improved further if the titrant is not added with a burette, but produced directly in the solution with a current applied by a generator cell. This also makes a titrant concentration determination obsolete. The Compact coulometric Karl Fischer Titrators offer particularly fast and precise titration of samples with a low water content from 1 ppm to 5%. The titration vessel is made completely from glass which ensures a uniquely low drift and hence makes the most accurate and precise results possible.

Diaphragm less Cell — for More Convenience
The user has the choice of current generator cell with or without diaphragm. For most samples the cell without diaphragm offers more convenience, as no catholyte is needed. Due to the unique design, the diaphragm less cell even suits the demands for very precise low water content determinations.

Solvent Manger — Prevents You from Chemical Contact
Users are protected against contact with chemicals using the Solvent Manager liquid handling device. It is fully controlled by the titrator and offers solvent exchange at One Click without additional user interaction. Operation is very simple and user contact with chemicals is avoided.

Elegant Automation — for Many Kinds of Samples
Gas phase extraction is the perfect solution for samples that are unable to be directly added into the titration vessel. In this process samples are placed into a sample boat or vial and moved to the oven or sample rack.

Technical data
Power supply Input voltage: 100–240 V ±10 %
Input frequency: 50–60 Hz
Primary connection socket: 3 pin, IEC C14
Power consumption: 24 VA. Connected load; 24 V DC , 1.25 A. Secondary connection plug 2 pin, DC plug.

Materials Titrator housing: Crastin PBT
Cover sheet: PET
Protective cover: Copolymer
Chassis: Stainless steel
Titration stand: Crastin PBT
Lid (titration beaker): Polypropylene
Threaded ring: Polypropylene
Three hole adapter: Polypropylene
Dispensing tube/extraction tube: FEP. Air tubes: Silicone
O-ring (screw top): EPDM/ O-ring (threaded ring): FEP / silicone
Sealing ring (bottle): PTFE / silicone/ Seal (dispensing tube / extraction tube): PTFE
Connecting piece Polypropylene

Ambient conditions /Ambient temperature +5 °C – 40 °C. Relative humidity Max. 80 % (non-condensing) at 31 °C, linear fall to 50 % at 40°C. Use In interior spaces. Overvoltage category II. Pollution degree 2

 

Testimonials

★★★★★