Peak Scientific Acrion N2 Nitrogen Gas Generator & Acrion Air Compressor

sku: 7771501
Out Of Stock
Ask a question
Condition : Excellent
Warranty : 30-Day Warranty, 100% Parts and Labor
Region : EU
$1,800.00
Apply For Finance
Make Offer
Enquiry Here
ADD TO CART
  • Make Peak Scientific
  • Hertz 50Hz/60Hz
  • Model Acrion N2 Nitrogen Generator & Acrion Air Compressor
  • Serial 771045334 & 771045892
  • Weight 42.0 Kg
  • Voltage 230V
  • Includes Power cord included |
  • Warranty 30-Day Warranty, 100% Parts and Labor
  • Dimensions 56.0cm x 42.0cm x 54.0cm
  • Shipping Type FedEx Ground
  • Item Condition Excellent
  • Manufacturing Date Does Not Apply

Product Information

"Peak Scientific Acrion N2 Nitrogen Gas Generator & Acrion Air Compressor The Acrion Air Compressor is designed specifically to minimize operator involvement Given that the system is installed as described in earlier sections and is serviced in accordance with the specified maintenance recommendations (see Service Requirements), then it should simply be a matter of turning the air compressor on when it is required. The air compressor will automatically produce the factory set flow and pressure as detailed in the Technical Specifications and as required by the Acrion Nitrogen generator. The generator compressor stops periodically to eject moisture from its drain bowls; this is controlled by a timer. When the compressor is running it is controlled by a pressure switch with two sets of limits: Output A : The high point turns the LEDS Blue indicating required pressure is available. The low point turns the LEDS Yellow indicating the pressure has dropped below the required level. Output B: The high point turns the compressor off indicating there has been no drop in pressure from the output and the demand has stopped. The low point will restart the compressor if the pressure is dropping. On Demand Gas: The air compressor system will produce compressed air on demand. If the application is operating and requires a gas flow, the system it is connected to will supply this to suit the requirements of the application. If the application requirement for gas stops, the system will also stop, once it has reached its upper set limit in the internal storage tanks. If the demand from the application starts again, the system will detect the demand for gas and will automatically start again to suit the demand. Usage: The air compressor is designed for indoor use only. It should be installed adjacent to the application(s) it is supplying. If this is not convenient then the unit can be sited elsewhere, however, consideration should be made of the lengths of pipe runs as pressure drops can result from extended runs of pipe. Performance of the air compressor (like all sophisticated equipment) is affected by ambient conditions. Note should also be taken to the proximity of Air Conditioning outlets. These can sometimes give rise to pockets of air with high relative humidity. Operation of the unit within such a pocket could adversely affect its performance. Consideration should also be given to the air flow around the unit. It is recommended that an air gap of 75mm (3) should be maintained down both sides and at the rear of the unit. Please refer to the drawing below for the general dimensions of the unit. Please ensure Generator is situated in a well-ventilated environment and is positioned to allow easy disconnection from the mains supply if required. Peak Scientific Acrion N2 generator On Demand Gas The generator will produce nitrogen on demand. If the application is operating and requires a gas flow, the system it is connected to will supply this to suit the requirements of the application. If the application requirement for gas stops, the system will also stop. If the demand from the application starts again, the system will detect the demand for gas and will automatically start again to suit the demand. Generator Environment The generator is designed for indoor use only. It should be installed adjacent to the application(s) it is supplying. If this is not convenient then the unit can be sited elsewhere, however, consideration should be made of the lengths of pipe runs as pressure drops can result from extended runs of pipe. The performance of the generator (like all sophisticated equipment) is affected by ambient conditions. Note should also be taken to the proximity of Air Conditioning outlets. These can sometimes give rise to pockets of air with high relative humidity. Operation of the unit within such a pocket could adversely affect its performance. Consideration should also be given to the air flow around the unit. It is recommended that an air gap of 75mm (3) should be maintained down both sides and at the rear of the unit. Please refer to the drawing below for the general dimensions of the unit."

Key Features

  • On-demand gas production for laboratory applications
  • Automatic nitrogen production based on application demand
  • Advanced air compressor designed to minimize operator involvement
  • Suitable for indoor use in laboratory environments
Specifications

  • Automatic on/off control based on application demand
  • Indoor use only with recommended air flow considerations
  • Gas production based on specified factory set flow and pressure levels
Weight

Metric: 42 kg
Imperial: 92.59404 lbs

Dimensions

Metric: 22.047256 cm x 16.535442 cm x 21.259854 cm
Imperial: 8.67296692992 in x 6.51951169216 in x 8.36626177192 in

Harmonized Code

841480

Harmonized Code Details

Air compressor, mounted on a wheeled chassis for towing, suitable for use in workshops