  • Make Thermo Scientific
  • Hertz 50Hz/60Hz
  • Model Vanquish Detector
  • Serial 8314617
  • Weight 21.0 Kg
  • Voltage 120V/220V
  • Includes Power cord included |
  • Warranty AS-IS
  • Dimensions 80.0cm x 61.0cm x 38.0cm
  • Shipping Type FedEx Ground
  • Item Condition AS-IS
  • Manufacturing Date 2019-10-21

Product Information

Achieve excellent linearity and noise performance across a wide operating range with the Thermo Scientific Vanquish Variable Wavelength Detector. Integrated into Thermo Scientific Vanquish HPLC and UHPLC systems, this detector offers versatile, robust, high-performance UV-Vis absorption detection for measuring a wide range of samples. With up to 250 Hz data acquisition, it stays ahead of current and future HPLC and UHPLC detection challenges. The detector provides a broad range of flow cells to match application requirements, minimize baseline drift and noise, and simplify method development. It is equipped with automated performance and wellness monitoring, predictive GLP features, and multiple safety mechanisms, ensuring accurate and reliable results.

Key Features

  • Integrated into Thermo Scientific Vanquish HPLC and UHPLC systems
  • Up to 250 Hz data acquisition rate
  • Broad range of flow cells to match application requirements
  • Automated performance and wellness monitoring
  • Predictive GLP features
  • Active temperature control of optics and electronics for minimizing baseline drift and noise
  • Wide wavelength range for detecting trace analytes and main compounds
  • Up to four absorption channels and spectral scans for simplified method development
Specifications

  • Data Collection Rate: Up to 250 Hz (Single Channel)
  • Detection Mode: UV-vis Detection (Up to 4 Channels)
  • Detector Type: Variable Wavelength; Single Beam
  • Type: Variable Wavelength Detector
  • Conductivity Wetted Parts(Flow Cells): Standard and semi-micro flow cell (Fused Silica, PEEK, PTFE, Stainless Steel Bio), semipreparative and UV monitor flow cells (Fused Silica, PEEK)
  • Drift: <0.1 mAU/h at 254 nm and dry standard flow cell
  • Noise: One Channel - <2.5 AU at 254 nm; Multiple Channels: <10 AU (typical <7 AU) at 254 nm and 280 nm
  • Wavelength Accuracy: 1 nm; Wavelength repeatability: 0.1 nm
  • Wavelength Range: 190-900 nm with deuterium and tungsten lamp
  • Lamp: Deuterium lamp, tungsten lamp
  • Linearity: <5% (typical <3%) at 2.5 AU caffeine, wavelength: 272 nm based on ASTM
  • Optical Bandwidth: 6 nm at 254 nm
  • PC Connection: USB 2.0; 3-port HUB to connect further Vanquish modules
  • Safety Features: Power-up diagnostics of optics, cooling fans, motors, and electronics; Leak detection and safe leak handling
  • Height: 160 mm
  • Length: 620 mm
  • Voltage: Power requirements - 100-240 V AC, 50/60 Hz, max. 150 W/255 VA
  • Description: Vanquish VWD-F, up to four channels available, 6 different flow cells available
  • Electrical Requirements: 100-240 V AC, 50/60 Hz, max. 150 W/255 VA
  • For Use With (Equipment): Vanquish UHPLC Systems
Weight

Metric: 44.0924 kg
Imperial: 97.23263 lbs

Dimensions

Metric: 62.0 cm x 16.535442 cm x 16.0 cm
Imperial: 24.409462 in x 6.5 in x 6.296256 in

Harmonized Code

90273000

Harmonized Code Details

Instruments and apparatus for physical or chemical analysis: Chromatographs and electrophoresis instruments

Testimonials

★★★★★

“REUZEit has been a great partner for our used equipment needs and always provide timely updates of new arrivals of consigned equipment.”

★★★★★

“Great company to work with. Tammy completed our first international equipment shipment with ease.”

★★★★★

“Fast response, open to adjusting schedule as needed, and great customer interaction.”

Need Answers? We’re Here to Help