Thermo Scientific Exactive Plus Orbitrap Mass Spectrometer
- Make Thermo Scientific
- Hertz 50Hz/60Hz
- Model Exactive Plus
- Serial SN02022P
- Weight 425.0 Lb
- Voltage 220V
- Includes Power cord included |
- Warranty AS-IS
- Dimensions 33.0in x 40.0in x 44.0in
- Shipping Type FedEx Ground
- Item Condition AS-IS
- Manufacturing Date Does Not Apply
Product Information
As dependable as seasoned lab scientists, the Thermo Scientific Exactive Plus Orbitrap Mass Spectrometer is a high-resolution, accurate-mass (HR/AM) full-scan mass spectra provider. With sophisticated features like scan speeds up to 12 Hz, mass resolution of up to 140,000 (FWHM) at m/z 200, and all-ion fragmentation options, this spectrometer is the ultimate solution for screening applications. Its unique functionality serves diverse fields including food safety, environmental analysis, clinical research, and drug metabolism studies. With its optional extended mass range (EMR) and improved detection capabilities, it's equally outstanding for biopharmaceutical and biological research. This spectrometer promises routine sub-ppm mass accuracy, optimal resolving power, maximum scan speeds, and a comprehensive mass range. Little-known fact: The S-Lens and HCD collision cell make this spectrometer an all-around compound-finding champion.
Key Features- High-resolution, accurate-mass (HR/AM) full-scan mass spectra
- Scan speeds up to 12 Hz and mass resolution of up to 140,000 (FWHM) at m/z 200
- Screening versatility from food safety to drug metabolism studies
- Optional extended mass range (EMR) and improved detection capabilities
- Routine sub-ppm mass accuracy
- Resolving power of up to 140,000 (FWHM) at m/z 200
- Maximum scan speed of 12 Hz
- Intrascan dynamic range of > 5,000:1
- Mass range of 50 to 6,000 m/z (standard mode) or 350 to 20,000 m/z (EMR mode)
- Full-scan MS analysis
- All-ion fragmentation with multiple dissociation techniques: In-source CID (collision-induced dissociation), HCD (higher-energy collisional dissociation, optional)
- Onsite upgradable from Exactive Plus mass spectrometer to Q Exactive mass spectrometer
- Hardware Specification: Thermo Scientific Ion Max API Source with Enhanced sensitivity and ruggedness, reduced chemical noise upon sweep gas application, among others
- Advanced ion guides for high sensitivity and ruggedness, vacuum system with differentially pumped vacuum system with final vacuum <1 10-9 mbar, Orbitrap Mass Analyzer with nitrogen-filled curved linear trap (C-Trap), highly efficient ion transfer to Orbitrap analyzer and 16-bit signal digitalization, and more.
- Data Acquisition: Ultrafast real-time data acquisition and instrument control system, automated calibration via instrument control software, automated gain control
- Installation Requirement: Power - 2 x 230 VAC 10% single phase, 15 Ampere, 50/60 Hz, with earth ground for the instrument, 120 or 230 VAC single phase with earth ground for the data system, Gas - Nitrogen supply required.
- Operating environment must be 1526 C (5978 F) and relative humidity must be 4070% with no condensation
Metric: 192.78 kg
Imperial: 425 lbs
Metric: 33 cm x 40 cm x 44 cm
Imperial: 12.99 in x 15.75 in x 17.32 in
902720
Harmonized Code DetailsThe chosen harmonized code is 902720 - Chromatographs and Electrophoresis Instruments. This category most accurately describes the type of equipment as it includes mass spectrometers alongside other similar laboratory instruments designed for separation and analysis, specifically supporting the structural or functional studies of biological macromolecules, including proteins and nucleic acids.
Testimonials
“REUZEit has been a great partner for our used equipment needs and always provide timely updates of new arrivals of consigned equipment.”
“Great company to work with. Tammy completed our first international equipment shipment with ease.”
“Fast response, open to adjusting schedule as needed, and great customer interaction.”