NuAire NU-425-600 Class II Type A2 Biosafety Cabinet
NuAire NU-425-600 Class II Type A2 Biosafety Cabinet
NuAire NU-425-600 Class II Type A2 Biosafety Cabinet
NuAire NU-425-600 Class II Type A2 Biosafety Cabinet
NuAire NU-425-600 Class II Type A2 Biosafety Cabinet
NuAire NU-425-600 Class II Type A2 Biosafety Cabinet
NuAire NU-425-600 Class II Type A2 Biosafety Cabinet
NuAire NU-425-600 Class II Type A2 Biosafety Cabinet
NuAire NU-425-600 Class II Type A2 Biosafety Cabinet
NuAire NU-425-600 Class II Type A2 Biosafety Cabinet
NuAire NU-425-600 Class II Type A2 Biosafety Cabinet
NuAire NU-425-600 Class II Type A2 Biosafety Cabinet

NuAire NU-425-600 Class II Type A2 Biosafety Cabinet

sku: 3369746
1 In Stock
Ask a question
Condition : Good
Warranty : AS-IS
Region : US
$2,499.00$5,000.00
Apply For Finance
Make Offer
Enquiry Here
ADD TO CART
  • Make NuAire
  • Hertz 60Hz US
  • Model NU-425-600 Class II Type A2
  • Serial 105641040606
  • Weight 1150.0 Lb
  • Voltage 120V
  • Includes Power cord included |
  • Warranty AS-IS
  • Dimensions 41.0in x 85.0in x 80.0in
  • Shipping Type Freight
  • Item Condition Good
  • Manufacturing Date Does Not Apply

Product Information

The NuAire NU-425-600 Class II Type A2 Biosafety Cabinet is designed to provide a safe, sterile environment for working with biological agents. This model has been meticulously tested for basic functionality, including the normal operation of vents, lights, and buttons. It conforms to the laminar flow principle and features an Energy Saver DC ECM motor for optimal energy efficiency and filter loading capacity. The biocontainment technology aids in obtaining control over product quality while reducing exposure to airborne biological or particulate chemical agents, as recommended by the CDC. The interior workspace dimensions ensure practical use for various laboratory procedures.

Key Features

  • Energy Saver DC ECM motor
  • Maintains inflow velocity of 100 LFPM (.51m/s) through the work access opening
  • HEPA filtered downflow air mixed with the inflow air from a common exhaust plenum
  • Exhaust airflow can be room re-circulated or exhausted outside using a canopy exhaust transition
  • All biologically contaminated ducts and plenums under negative pressure or surrounded by negative pressure
Specifications

  • Maintains inflow velocity of 100 LFPM (.51m/s) through the work access opening
  • HEPA filtered downflow air mixed with the inflow air from a common exhaust plenum
  • Air exhausted outside using a canopy exhaust transition or room re-circulation
  • All biologically contaminated ducts and plenums constantly under negative pressure
  • Class II Type A2 Biological Safety Cabinet
  • Interior Workspace Dimensions: Height - 29 in, Width - 71 in, Depth - 24 in
Weight

Metric: 521.63 kg
Imperial: 1150 lb

Dimensions

Metric: 85 cm x 213 cm x 58 cm
Imperial: 33.46 in x 83.85 in x 22.83 in

Harmonized Code

84198998

Harmonized Code Details

The most likely harmonized code is 84198998 for Medical, Surgical, or Laboratory Sterilizers, and the reasoning is based on the equipment's function and intended use.

Testimonials

★★★★★

“REUZEit has been a great partner for our used equipment needs and always provide timely updates of new arrivals of consigned equipment.”

★★★★★

“Great company to work with. Tammy completed our first international equipment shipment with ease.”

★★★★★

“Fast response, open to adjusting schedule as needed, and great customer interaction.”

Need Answers? We’re Here to Help