1 11
Thermo Accela Detector HPLC/UHPLC LightPipe High Sensitivity 120V 80Hz
Thermo Accela Detector HPLC/UHPLC LightPipe High Sensitivity 120V 80Hz
Thermo Accela Detector HPLC/UHPLC LightPipe High Sensitivity 120V 80Hz
Thermo Accela Detector HPLC/UHPLC LightPipe High Sensitivity 120V 80Hz
Thermo Accela Detector HPLC/UHPLC LightPipe High Sensitivity 120V 80Hz
Thermo Accela Detector HPLC/UHPLC LightPipe High Sensitivity 120V 80Hz
Thermo Accela Detector HPLC/UHPLC LightPipe High Sensitivity 120V 80Hz
Thermo Accela Detector HPLC/UHPLC LightPipe High Sensitivity 120V 80Hz
Thermo Accela Detector HPLC/UHPLC LightPipe High Sensitivity 120V 80Hz
Thermo Accela Detector HPLC/UHPLC LightPipe High Sensitivity 120V 80Hz
Thermo Accela Detector HPLC/UHPLC LightPipe High Sensitivity 120V 80Hz

Thermo Accela Detector HPLC/UHPLC LightPipe High Sensitivity 120V 80Hz

sku: 3370904
1 In Stock

Thermo Scientific

Accela
US REUZEit West Coast US - R
AS-IS
$1,999.00
$2,250.00
-11% OFF
Make Offer Enquiry Here
Add to cart Download flyer

Details

  • Category
    HPLC / FPLC / GC / CE
  • Dimension
    21.0in x 15.0in x 33.0in
  • Serial
    930134
  • Shipping Type
    FedEx Ground
  • Manufacturing
    Does Not Apply
  • Voltage / Hertz
    120V / 50Hz/60Hz

Description

Product Information

This Thermo Accela PDA 80 Hz Detector is recognized for its robust modular system, enhancing versatility and efficiency in applications from industrial QA/QC to advanced drug discovery. It provides seamless customization for any laboratory setup. The detector utilizes Thermo LightPipe technology for rapid, high-sensitivity photodiode array detection. Key features include a 1 cm path length with a 2 L flowcell and a 5 cm path length with a 10 L flow cell for U-HPLC and HPLC applications, respectively, offering superior sensitivity. Its fiber-optic beam shaper ensures the highest peak resolution. Despite its fair condition, requiring new lamps, and having cosmetic wear, it remains functional. It is suitable for entities seeking cost-effective analytical solutions.


Key Features
  • High Sensitivity LightPipe Technology
  • 1 cm and 5 cm path length
  • 2 L and 10 L LightPipes
  • Fast Photo Diode Array Detection
  • Configured for HPLC/UHPLC applications
  • Fiber-Optic Beam Shaper
  • Flexible customizable modular system

Specifications
  • Wavelength Range: 190-800 nm at 1 nm increment
  • Wavelength Accuracy: 1 nm at 254 nm and 640 nm
  • Wavelength Calibration: Using Holmium oxide solution
  • Wavelength Resolution: 1.2 nm (512 pixel array)
  • Absorbance Non-Linearity: < 5% at 2.0 AU at 257 nm
  • Absorbance Range: -2.0 to +4.0 AU
  • Drift: < 1 mAU/hr after warm-up at 254 nm at a stable temperature (1C)
  • Light Source: Pre-aligned Deuterium and Tungsten lamps
  • Scan Rate: User selectable: up to 80 Hz
  • Discrete Channels: Three wavelength selectable channels
  • Short-Term Noise across varied scan rates
  • Warm-up Time: 90 min
  • Cell Dimensions: 10 mm, 2 L LightPipe; 50 mm, 10 L LightPipe
  • Cell Pressure Range: 0-1000 psi
  • Analog Outputs with 20-bit conversion
  • Diodes: 512 with 1.2 nm spacing

Weight

Imperial: 120.0 Pounds

Metric: 54.43 Kilograms


Shipping Dimensions

Imperial: 25.2 lb x 18.0 lb x 39.6 lb

Metric: 64.01 cm x 45.72 cm x 100.58 cm


Harmonized Code

9027309000


Harmonized Code Details

The code 9027309000 refers to instruments and apparatus for physical or chemical analysis, specifically for laboratories using optical radiations like spectrophotometers. This code is appropriate given the function and technology utilized in the Thermo Accela Detector.