Qiagen QIAsymphony SP Automated Nucleic Acid Purification Instrument
Qiagen QIAsymphony SP Automated Nucleic Acid Purification Instrument
Qiagen QIAsymphony SP Automated Nucleic Acid Purification Instrument
Qiagen QIAsymphony SP Automated Nucleic Acid Purification Instrument
Qiagen QIAsymphony SP Automated Nucleic Acid Purification Instrument
Qiagen QIAsymphony SP Automated Nucleic Acid Purification Instrument
Qiagen QIAsymphony SP Automated Nucleic Acid Purification Instrument
Qiagen QIAsymphony SP Automated Nucleic Acid Purification Instrument
Qiagen QIAsymphony SP Automated Nucleic Acid Purification Instrument
Qiagen QIAsymphony SP Automated Nucleic Acid Purification Instrument
Qiagen QIAsymphony SP Automated Nucleic Acid Purification Instrument
Qiagen QIAsymphony SP Automated Nucleic Acid Purification Instrument

Qiagen QIAsymphony SP Automated Nucleic Acid Purification Instrument

sku: 3375377
1 In Stock

Qiagen

QIAsymphony SP
US REUZEit West Coast US - R
30-Day Warranty On Part
$2,000.00
Apply For Finance Make Offer Enquiry Here
Add to cart Download flyer

Details

  • Category
    Molecular Biology
  • Dimension
    28.0in x 50.0in x 40.0in
  • Serial
    35357
  • Shipping Type
    Freight
  • Manufacturing
    Does Not Apply
  • Voltage / Hertz
    100-240v / 50Hz/60Hz

Description

Product Information

The Qiagen QIAsymphony SP is a sophisticated nucleic acid purification system ideal for molecular diagnostics and research applications. This unit, designed for professional use, facilitates the automated purification of high-quality genomic DNA, RNA, and pathogen DNA/RNA from up to 96 samples in four batches. Notably, it features traceability and LIMS compatibility, ensuring efficient and error-minimized workflows. It can process a comprehensive range of sample types and volumes, making it an exceptionally versatile tool in the laboratory. While the instrument powers on, it displays error code E300009 during startup, indicating a minor issue that likely requires maintenance. The touchscreen is responsive, yet the unit exhibits minor cosmetic wear from previous laboratory use.


Technician comment

The Qiagen QIAsymphony SP powers on, but an error message appears during startup: “Error E300009 – An error from the MaintenanceScheduler was detected during initialization of the system. The system will now restart.” The touchscreen is responsive, and the unit displays startup activity before the error occurs. No further testing was performed due to the initialization failure. The unit is preowned from a laboratory environment and shows moderate cosmetic wear consistent with prior use.


Key Features
  • Processes 1-96 samples in 4 batches
  • Multiple sample types including genomic DNA, RNA
  • Compatible with QIAsymphony DSP kits
  • Traceability and LIMS compatibility
  • Customizable protocols
  • Up to 10 ml sample volume

Specifications
  • Voltage: 100-240v
  • Frequency: 50Hz/60Hz
  • Sample Capacity: 1-96 samples
  • Maximum Sample Volume: 10 ml
  • Error Code: E300009 during startup
  • Minimal cosmetic wear

Weight

Imperial: 470.4 Pounds

Metric: 213.37 Kilograms


Shipping Dimensions

Imperial: 33.6 lb x 60.0 lb x 48.0 lb

Metric: 85.34 cm x 152.4 cm x 121.92 cm


Harmonized Code

84798200


Harmonized Code Details

The code 84798200 is for machines and mechanical appliances having individual functions, not specified elsewhere. It is appropriate given the nature of the QIAsymphony SP as a specialized laboratory instrument.