Thermo Scientific TSQ Vantage Mass Spectrometer with Pumps for High Sensitivity Analysis
Thermo Scientific
Details
-
CategoryMass Spectrometry
-
Dimension34.0in x 60.0in x 61.0in
-
SerialTQU02514
-
Shipping TypeFreight
-
ManufacturingDoes Not Apply
-
Voltage / Hertz230V / 50Hz/60Hz
Description
The Thermo Scientific TSQ Vantage Mass Spectrometer with Pumps on a custom Omni table is designed for precise quantitative analysis of small molecules, peptides, biosimilars, and biologics, offering exceptional sensitivity and reduced chemical noise. Featuring G2 ion optics and a HESI-II ion source, the TSQ Vantage increases ion transmission and improves flow performance, enabling confident, reliable assay accuracy. Although the system powers on and performs basic tests, comprehensive testing was not conducted. The vacuum pumps, tested to 0.005 mbar, and the mass spectrometer exhibit signs of cosmetic wear due to normal usage. Note: the soundproofing material shows signs of wear. This model is equipped with an S-Lens for efficient ion focus and a high-speed collision cell designed to avoid cross-talk, meeting the demands of GLP for reproducibility. Power cords and user manuals are included, but software, licenses, and computer are not.
Technician comment
Unit was sourced from a working lab environment. System powers on, but full functional testing was not performed. Software, licenses, and PC are not included. The vacuum pumps were tested and reached approximately 0.005 mbar. The instrument and Omni table show minor cosmetic wear and paint chipping consistent with normal use. Note: (The soundproofing material in the vacuum compartment is flaking and showing signs of wear.) Includes: TSQ Vantage MS with HESI Ion Source, Edwards E2M30 Pumps, Custom Omni Table
Key Features
- Top sensitivity with G2 ion optics
- HESI-II for improved flow rates
- Minimum chemical noise with HyperQuad
- Fast scan speeds of up to 5000 u/s
- S-Lens for high ion focus and reduced maintenance
- Zero cross-talk collision cell
Specifications
- Mass Range: m/z 10-1500 daltons (Da)
- Resolution: 7500 (FWHM) at m/z 508 of polytyrosine with adjustable resolution better than 0.1 Da across range
- Mass Stability: within 0.050 Da over 24 hours between 18-21C
- Power Requirements: 230V 50/60Hz 15A
- Includes: HESI Ion Source, Edwards E2M30 Pumps
- On Custom Omni Table
Weight
Imperial: 660.0 Pounds
Metric: 299.37 Kilograms
Shipping Dimensions
Imperial: 40.8 lb x 72.0 lb x 73.2 lb
Metric: 103.63 cm x 182.88 cm x 185.93 cm
Harmonized Code
902730
Harmonized Code Details
Harmonized code 902730 covers spectrometers and spectrophotometers; it is appropriate for the TSQ Vantage Mass Spectrometer given its function and application in quantitative analysis.