Thermo Scientific TSQ Vantage Mass Spectrometer High Sensitivity
Thermo Scientific TSQ Vantage Mass Spectrometer High Sensitivity
Thermo Scientific TSQ Vantage Mass Spectrometer High Sensitivity
Thermo Scientific TSQ Vantage Mass Spectrometer High Sensitivity
Thermo Scientific TSQ Vantage Mass Spectrometer High Sensitivity
Thermo Scientific TSQ Vantage Mass Spectrometer High Sensitivity
Thermo Scientific TSQ Vantage Mass Spectrometer High Sensitivity
Thermo Scientific TSQ Vantage Mass Spectrometer High Sensitivity
Thermo Scientific TSQ Vantage Mass Spectrometer High Sensitivity
Thermo Scientific TSQ Vantage Mass Spectrometer High Sensitivity
Thermo Scientific TSQ Vantage Mass Spectrometer High Sensitivity
Thermo Scientific TSQ Vantage Mass Spectrometer High Sensitivity
Thermo Scientific TSQ Vantage Mass Spectrometer High Sensitivity

Thermo Scientific TSQ Vantage Mass Spectrometer High Sensitivity

sku: 3375644
1 In Stock

Thermo Scientific

TSQ Vantage
US West Coast US - R
30-Day Warranty On Part
$5,000.00
$20,000.00
-75% OFF
Apply For Finance Make Offer Enquiry Here
Add to cart Download flyer

Details

  • Category
    Mass Spectrometry
  • Dimension
    31.0in x 24.0in x 24.0in
  • Serial
    TQU03338
  • Shipping Type
    Freight
  • Voltage / Hertz
    220V / 50Hz/60Hz

Description

Product Information

The Thermo Scientific TSQ Vantage Mass Spectrometer, manufactured in the United States, is a pre-owned unit in working condition. Designed for high precision and accuracy, it is ideal for bioanalytical, clinical research, environmental, and proteomics applications. The TSQ Vantage features G2 ion optics, HESI-II design, and HyperQuad quadrupole mass filters, ensuring low chemical noise and high sensitivity. It supports a mass range of m/z 10-1500 Da and offers high-resolution selected reaction monitoring (H-SRM). The unit requires validation and calibration for optimal results. Note that the ion source is not included.


Technician comment

This unit powers on. Communications indicator is blinking orange and the system will need to be connected to the software for further testing. Unit shows slight wear from normal use. System will need to be validated and calibrated to ensure accurate results. Inquire about system validation for an additional cost. Ion source is not included. Please see photos for details.


Key Features
  • G2 ion optics for superior precision
  • HESI-II design for improved flow performance
  • HyperQuad quadrupole mass filters
  • High-resolution selected reaction monitoring (H-SRM)
  • Zero-cross-talk collision cell

Specifications
  • Voltage: 220V
  • Hertz: 50Hz/60Hz
  • Mass Range: m/z 10-1500 Da
  • Resolution: 7500 (FWHM) at m/z508
  • Mass Stability: within 0.050 Da over 24 hours
  • Collision gas: 99.995% pure Argon
  • Sheath gas: 99% pure Nitrogen
  • Maximum sheath gas consumption: ~ 20 L/min

Weight

Imperial: 300.0 Pounds
Metric: 136.08 Kilograms


Shipping Dimensions

Imperial: 37.2 in x 28.8 in x 28.8 in
Metric: 94.49 cm x 73.15 cm x 73.15 cm


Harmonized Code

9027.20


Harmonized Code Details

HS Code 9027.20 covers mass spectrometers, used for measuring and analyzing the mass-to-charge ratio of ions. This classification is appropriate given the equipment's function in analytical applications.